Compared
LoRaWAN Pressure Sensors Compared: MacSync LPS Xx vs Milesight EM500-PP vs Dragino PS-LB vs Decentlab DL-PR21 vs Ellenex PTS2-L
Five LoRaWAN pressure transducers for water networks, hydrant lines, pumping stations, plants and pipelines, for anyone weighing an alternative to the EM500-PP, the PS-LB kit, the Decentlab PR21 or the Ellenex PTS2-L. The differences are the number of ranges on one platform, how accuracy and stability are worded, whether the pressure reference is stated, battery against DC, Class C from a phone, IN865 as standard and where the hardware and the support come from.
Macnman product on this page: MacSync LPS Xx
Side by side
The published figures
Every value is as each manufacturer publishes it, checked on 25 October 2026. Where a page does not state a figure, the cell says so.
| Compare | Macnman MacSync LPS Xx | Milesight EM500-PP | Dragino PS-LB | Decentlab DL-PR21 | Ellenex PTS2-L |
|---|---|---|---|---|---|
| Ranges | 0–2.5, 0–5 or 0–10 MPa, three models on one node | 0–1.6 MPa (16 bar), one range | Threaded probe by order code, −0.1 to 60 MPa; immersion probe to 100 m | −0.1 to 1 MPa (−1 to 10 bar) | 0–0.05 to 0–100 MPa, selectable |
| Accuracy wording | ±0.05 % FS, basis not stated | ±0.5 % FS | 0.2 % FS (probe maker's figure) | ±0.15 % FS linearity; ±0.7 % FS total error band | ±0.25 % of span typical (linearity, hysteresis, repeatability) |
| Temperature effect and stability | ±0.02 % FS per °C; long-term stability not stated | ±0.3 % FS per year | 0.2 % FS per year; zero drift 0.02–0.03 % FS per °C | Not stated on the page | Zero and span ≤±0.02 % FS per °C; ≤0.2 % of span per year |
| Overload | 200 % overload, 300 % burst | 150 % FS | 200 % | Not stated on the page | 300 % below 1 bar, 150 % above |
| Pressure reference | Not stated | Vented gauge | Not stated on the product page | Not stated on the page | Vented, sealed or absolute, selectable |
| Thread and wetted material | G1/4, SS316 element | G1/2 male, SS316L | Threaded probe; 316 stainless immersion variant | G1/4 pipe thread | G1/4 male; SS304 body, SS316 diaphragm, Viton seal |
| Ingress protection | Node IP65 (IP67 option); transducer IP65 | Transducer IP65; transceiver IP67 | Probe IP65 (immersion IP68); node not on the page | Not stated on the page | IP66 |
| Power | 19 Ah: about 2 / 4 / 7+ years at 5 / 15 / 60-minute reports; or 9–36 V DC | 19 Ah ER34615: 10 years at 10-minute reports, lab conditions | 8,500 mAh, up to 5 years; PS-LS solar with 3,000 mAh | Two C alkaline cells | Replaceable 3.6 V lithium: 50,000+ readings / 20,000+ transmissions |
| Class and configuration | Class A, Class C from the Maya app; BLE and downlink; MacTalk device to device | Class A; NFC, USB-C and downlink | LoRaWAN 1.0.3 Class A; BLE 5.1; OTA | Class A | Class A; Class C on request |
| Bands | IN865 standard; RU864, EU868, US915, AU915 | IN865 among eight plans | IN865 among the listed bands | Not stated on the page | AS923, EU868, US915, AU915; others on request, IN865 not listed |
| Stored records | Not stated | 1,000 entries | Not on the page | Not on the page | Not stated |
| Designed and made in | Pune, India; WPC compliant, RoHS | China | China | Switzerland | Australia and the United States |
Figures for the other products are taken from their manufacturers' published pages, checked on 25 October 2026, and may change; check the linked sources before you order. Milesight, Dragino, Decentlab and Ellenex are trademarks of their respective owners.
Where each fits
What the table means for your site
Where the MacSync LPS Xx fits
Many points across a zone, a ring main or a plant that need monitoring and alerts rather than transient capture: three ranges to 10 MPa on one node, SS316 on G1/4, battery or 9–36 V DC, Class C and MacTalk from a phone, IN865 as standard with WPC compliance, made and supported in Pune. Its datasheet is silent on the pressure reference, long-term stability, resolution and stored records, and this comparison says so.
Where the Milesight EM500-PP fits
A single 16 bar vented-gauge sensor with a well documented sheet: stability per year, 1,000 stored entries, NFC setup and a lab-rated ten-year battery. One range, no DC variant, no Class C, imported.
Where the Dragino PS-LB fits
The lowest-cost route, sold in India through marketplaces: a node that reads a third-party threaded or immersion probe chosen by order code, with the probe maker's figures. Node enclosure and cable are not on the product page; support is from Shenzhen.
Where the Decentlab DL-PR21 fits
Swiss environmental-grade sensing with linearity and total error band stated separately, on alkaline cells; one range per model, no DC, bands and ingress rating not on its page.
Where the Ellenex PTS2-L fits
The most complete datasheet of the five: selectable ranges to 100 MPa, vented, sealed or absolute reference, zero and span coefficients and stability per year. IN865 is not listed and battery life is given in transmissions rather than years.
Get a quote
Need a quote for the MacSync LPS Xx?
Tell us how many you need and where they are going. A product engineer replies within one working day with availability, lead time and the right variant, and will tell you honestly if another unit fits your site better.
- Reply within one working day
- Designed and built in Pune, India
- WPC compliant, RoHS conformant
Questions
Choosing between them
Milesight states a vented gauge reference and Ellenex offers vented, sealed or absolute. The MacSync LPS Xx, Dragino PS-LB and Decentlab DL-PR21 pages do not state it; ask Macnman for the engineering note before a vacuum or altitude application.
The MacSync LPS Xx, designed and manufactured in Pune, with WPC compliance and RoHS on its datasheet and IN865 as the shipped plan. Milesight and Dragino list IN865 among their plans; Ellenex does not list it; Decentlab's page does not state bands.
None of the five is a utility transient logger. All sample at intervals of a minute or more; a DMA transient analysis needs a logger that samples many times a second, placed at a few critical points beside LoRaWAN sensors at many.
Sources
- Macnman MacSync LPS Xx datasheet
- Milesight EM500-PP product page
- Dragino PS-LB / PS-LS product page
- Decentlab DL-PR21 product page
- Ellenex PTS2-L product page
Other comparisons
- LoRaWAN T&H Sensor · Macnman vs Milesight vs Dragino vs SenseCAP
- Milesight vs SenseCAP · LoRaWAN CO₂ Sensor
- RS485 to LoRaWAN · Macnman vs Dragino vs Milesight vs RAK
- 4-20mA to LoRaWAN · Macnman vs Dragino vs Milesight
- LoRaWAN Ultrasonic Level · Macnman vs Milesight vs Dragino
- SenseCAP vs Dragino · LoRaWAN Soil Sensor
- Milesight vs RAK · Outdoor LoRaWAN Gateway
- Milesight vs Dragino · LoRaWAN IO Controller
- LoRaWAN Parking Sensor · Macnman vs MOKO vs Nwave vs Bosch
- Milesight vs Dragino vs SenseCAP · 7-in-1 Soil Sensor
- Milesight vs SenseCAP vs Dragino · LoRaWAN Weather Station
- Hydreon vs Decentlab vs Dragino · LoRaWAN Rain Sensor
- Milesight vs Zonewu vs Daviteq · Gas Sensors
- Dragino vs SenseCAP vs RAK · Soil pH Sensor
- Tata vs Genus vs Esyasoft · Gas Meter Module
Let‘s make it easy - reach out now!
Let’s bring it to life!
Let‘s Make it Easy
Reach Out Now
We are always ready
to help and
answer your
questions
Call
+91 7972856163
+91 9096830856
Location
Office-15 Bibwewadi, Pune, Maharashtra 411037
Get in Touch
Define your goals and all to value your time