Compared
LoRaWAN CO₂ Sensors Compared: MacSync LCO2 vs Milesight EM500-CO2 vs SenseCAP S2103
Three LoRaWAN CO₂ sensors with temperature and humidity on board. They differ in CO₂ range, stated accuracy, whether a mains-powered version exists, and how they are configured and supported.
Macnman product on this page: MacSync LCO2
Side by side
The published figures
Every value is as each manufacturer publishes it, checked on 7 October 2026. Where a page does not state a figure, the cell says so.
| Compare | Macnman MacSync LCO2 | Milesight EM500-CO2 | SenseCAP S2103 |
|---|---|---|---|
| CO₂ range | 400–2,000 ppm (X1) or 400–5,000 ppm (X2) | 400–5,000 ppm | 400–10,000 ppm |
| CO₂ accuracy | ±(50 ppm + 5% of reading) · repeatability ±10 ppm · drift ±(5 ppm + 0.5%) per year | ±(30 ppm + 3% of reading) | ±(30 ppm + 3% of reading), ±10% in the extended range |
| Temperature and humidity | −30 to +70 °C · ±0.3 °C · 0–100% RH · ±3% RH | Temperature, humidity and barometric pressure included; accuracies not on the page checked | −40 to +85 °C · ±0.2 °C · 0–100% RH · ±1.8% RH |
| Battery | 19 Ah Li-SOCl₂ · about 2 years at 5-minute and 7+ years at hourly reporting | 19,000 mAh ER34615, replaceable · up to 10 years | D-size Li-SOCl₂, replaceable · up to 10 years |
| Mains-powered version | 9–36 V DC variants (8512, 8532) | Battery only | Battery only |
| Enclosure | Glass-filled nylon · IP65, IP67 optional · ~175 g | IP65 | IP66 |
| Operating temperature | −40 to +80 °C | Not on the page checked | Not on the page checked |
| LoRaWAN | v1.0.4 · Class A, Class C via the app · OTAA | Class A | Class A |
| Bands | IN865 · RU864 · EU868 · US915 · AU915 · KR920 · AS923 | Regional variants; see datasheet | Regional variants; see datasheet |
| Configuration | Maya app over Bluetooth · downlink | NFC via mobile app · downlink | SenseCAP Mate app over Bluetooth |
| Gateway-free option | MacTalk and Bluetooth versions | — | — |
| Designed and made in | Designed and manufactured in Pune, India | Milesight, Xiamen, China | Seeed Studio, Shenzhen, China |
Figures for the other products are taken from their manufacturers' published datasheets and product pages, checked on 7 October 2026, and may change; check the linked sources before you order. Milesight, Dragino, SenseCAP and RAK are trademarks of their respective owners.
Where each fits
What the table means for your site
Where the MacSync LCO2 fits
Buildings and plants that want the same sensor in battery and DC-powered forms, a range matched to the room (2,000 ppm for offices, 5,000 ppm for plant rooms and labs), an operating range to +80 °C, and Indian manufacture with WPC compliance and local support. Its stated CO₂ accuracy is wider than the other two, so if a tighter published figure matters for a compliance use, read the datasheets closely.
Where the Milesight EM500-CO2 fits
Outdoor and harsh-environment CO₂ monitoring with barometric pressure on board and a tighter stated accuracy, on a replaceable 19 Ah cell. It is battery-only.
Where the SenseCAP S2103 fits
The widest CO₂ range of the three, to 10,000 ppm, with the tightest stated temperature and humidity accuracy, in an IP66 housing. It is battery-only and is configured from a phone app over Bluetooth.
Get a quote
Need a quote for the MacSync LCO2?
Tell us how many you need and where they are going. A product engineer replies within one working day with availability, lead time and the right variant, and will tell you honestly if another unit fits your site better.
- Reply within one working day
- Designed and built in Pune, India
- WPC compliant, RoHS conformant
Questions
Choosing between them
The Milesight EM500-CO2 and SenseCAP S2103 both state ±(30 ppm + 3% of reading); the MacSync LCO2 states ±(50 ppm + 5% of reading) with ±10 ppm repeatability and a published yearly drift figure. For ventilation control, all three resolve the difference between a fresh room and a stale one; for a compliance record, choose on the figure your standard requires.
Offices, classrooms and meeting rooms rarely exceed 2,000 ppm, so the X1 is the usual choice. Labs, plant rooms, warehouses with forklifts and ripening chambers can run higher, which is what the 5,000 ppm X2 is for.
The MacSync LCO2 has 9–36 V DC variants for continuous CO₂ monitoring where power exists. The EM500-CO2 and S2103 are battery-only on the pages checked.
Let‘s make it easy - reach out now!
Let’s bring it to life!
Let‘s Make it Easy
Reach Out Now
We are always ready
to help and
answer your
questions
Call
+91 7972856163
+91 9096830856
Location
Office-15 Bibwewadi, Pune, Maharashtra 411037
Get in Touch
Define your goals and all to value your time