Compared

4-20mA to LoRaWAN Converters Compared: MacSync LX1 vs Dragino PS-LB-NA vs Milesight UC501 vs SenseCAP S2100

Four devices that put an existing 4–20 mA or 0–10 V transmitter on LoRaWAN® without mains power at the instrument. They differ in how many loops they read, how they power the sensor, the battery they carry, the enclosure and the LoRaWAN class.

Macnman product on this page: MacSync LX1

Side by side

The published figures

Every value is as each manufacturer publishes it, checked on 10 October 2026. Where a page does not state a figure, the cell says so.

CompareMacnman MacSync LX1Dragino PS-LB-NAMilesight UC501 / UC502Seeed SenseCAP S2100
Analog inputs2 switchable channels, each 4–20 mA, 0–10 V or digital input1 × 0–20 mA · 1 × 0–30 V2 × analog inputs, each 4–20 mA or 0–10 V2 × 4–20 mA · 2 × 0–10 V; one interface type in use at a time
Resolution12-bit0.001 mA resolution · 0.02 mA accuracy12-bitNot on the page checked
Powers the sensorYes: selectable output level, 0–2,000 ms warm-up5 V and 12 V outputs2 × 3.3 V and 2 × 5 / 9 / 12 V, switchableNot on the page checked
Other interfacesRS485 Modbus RTU as an alternative modeNot on the page checkedRS232 or RS485 · SDI-12 · 2 × GPIORS485 Modbus RTU · 1 × GPIO, level or pulse
BandsIN865 · RU864 · EU868 · US915 · AU915CN470 · EU433 · KR920 · US915 · EU868 · AS923 · AU915 · IN865CN470 · IN865 · EU868 · RU864 · US915 · AU915 · KR920 · AS923IN865 · EU868 · US915 · AU915 · AS923
LoRaWANv1.0.4 · Class A, Class C via the app · OTAAv1.0.3 · Class AUC501 Class A and C · UC502 Class A; version not on the page checkedv1.0.3 · Class A
Power19 Ah battery variant, or 9–36 V DC variant8,500 mAh Li-SOCl₂ cell; solar version with a 3,000 mAh Li-ion cellUC501: 2 × 2,550 mAh rechargeable cells and a solar panel · UC502: 3 × 9,000 mAh cells · or 5–24 V DC19 Ah D-size cell, or external 12 V DC
Battery life statementDepends on the sensor it powers, the warm-up time and the interval; estimated for each project“Up to 5 years”; conditions not on the page checkedNot on the page checked“Up to 10 years”; conditions not on the page checked
EnclosureIP65, IP67 optional · −40 to +80 °CIP rating not on the page checked · −40 to +85 °CIP68 · −20 to +60 °C (UC501), −30 to +70 °C (UC502)IP66 · −40 to +85 °C
ConfigurationMaya app over Bluetooth · downlinkBluetooth · downlink · OTA firmwareNFC app · USB-C · downlinkBluetooth app
Designed and made inDesigned and manufactured in Pune, India · WPC compliantDragino, Shenzhen, ChinaMilesight, Xiamen, ChinaSeeed Studio, Shenzhen, China

Figures for the other products are taken from their manufacturers' published product pages and documentation, checked on 10 October 2026, and may change; check the linked sources before you order. Dragino, Milesight, Seeed and SenseCAP are trademarks of their respective owners.

Where each fits

What the table means for your site

Where the MacSync LX1 fits

Pressure, level and flow transmitters at tanks, borewells, pipelines and plant rooms in India, where the converter has to power the transmitter and survive outdoors: a 19 Ah battery variant or a 9–36 V DC variant, IP65 with an IP67 option, −40 to +80 °C, and the same hardware reads RS485 Modbus. A MacTalk version links to a MacSet controller with no gateway. Indian manufacture, WPC compliance and support from Pune come with it.

Where the Dragino PS-LB-NA fits

A single current input and a single voltage input with fine resolution, 5 V and 12 V outputs for the sensor and an 8,500 mAh cell, with a solar version. Its page gives no IP rating, so check the manual for an outdoor installation.

Where the Milesight UC501 / UC502 fits

Sites that need more than analog: two switchable analog inputs together with RS232 or RS485, SDI-12 and GPIO, several sensor supply voltages, an IP68 enclosure and NFC configuration. The UC501 runs on rechargeable cells with a solar panel and the UC502 on three 9,000 mAh cells.

Where the SenseCAP S2100 fits

One sensor per logger. The page describes it as a single-channel collector that uses one protocol at a time, chosen from 4–20 mA, 0–10 V, RS485 Modbus RTU or GPIO, on a 19 Ah cell in an IP66 enclosure. The page does not describe a supply output for the sensor.

Get a quote

Need a quote for the MacSync LX1?

Tell us how many you need and where they are going. A product engineer replies within one working day with availability, lead time and the right variant, and will tell you honestly if another unit fits your site better.

  • Reply within one working day
  • Designed and built in Pune, India
  • WPC compliant, RoHS conformant

Questions

Choosing between them

The MacSync LX1 supplies the connected sensor from a selectable power output, with a warm-up time of 0 to 2,000 ms before each reading. The Dragino PS-LB-NA page lists 5 V and 12 V outputs, and the Milesight UC501 / UC502 page lists 3.3 V and switchable 5, 9 and 12 V outputs. The SenseCAP S2100 page checked does not describe a sensor supply output. In every case, compare the output with the transmitter’s minimum supply voltage before ordering.

The MacSync LX1 has two analog channels, each set to 4–20 mA, 0–10 V or digital input. The Milesight UC501 / UC502 has two switchable analog inputs. The Dragino PS-LB-NA has one current input and one voltage input. The SenseCAP S2100 lists two current and two voltage channels, but its page says only one interface type is used at a time.

The MacSync LX1 is designed and manufactured in Pune and is WPC compliant for the IN865 band; support comes from the engineers who built it, in Indian Standard Time. The Dragino, Milesight and Seeed devices are imported, with IN865 versions available.

With care, because the sensor usually uses more energy than the radio. The Dragino page says up to 5 years and the SenseCAP page up to 10 years, without the conditions. A transmitter that needs a long warm-up or a short reporting interval shortens any of these figures. Ask each supplier for an estimate with your transmitter model and interval; Macnman provides one for the MacSync LX1 on request.

Got an IoT idea?

Let’s bring it to life!

flag image

WPC compliant · RoHS · a product engineer replies within one working day

Let‘s Make it Easy

Reach Out Now

Icon

Contact to Sales

Talk to our friendly team

chat@macnman.com
Icon

Call Us

24 X 7 Always On

+91 7972856163
Icon

Contact to Support

We are here to help

support@macnman.com
Icon

Visit Us

Visit our office HQ

View on Google Map

Socials

Use of this website and purchase of Macnman products are subject to our Terms and Conditions.