RS485 Modbus to LoRaWAN Converters Compared: MacSync LX1 vs Milesight UC300 vs Dragino RS485-LN
Three ways to put an existing Modbus meter, PLC or transmitter on LoRaWAN. One is a battery or DC datalogger with analog inputs, one is a mains-powered indoor controller with relays, and one is a mains-powered RS485 bridge.
Macnman product on this page: MacSync LX1
Side by side
The published figures
Every value is as each manufacturer publishes it, checked on 7 October 2026. Where a page does not state a figure, the cell says so.
| Compare | Macnman MacSync LX1 | Milesight UC300 | Dragino RS485-LN |
|---|---|---|---|
| Inputs | 1 × RS485 Modbus RTU, 1,200–115,200 baud · 2 × 4–20 mA · 2 × 0–10 V · 2 × digital (RS485 and analog share the terminals) | 1 × RS485 Modbus RTU · 1 × RS232 · 4 × digital inputs with pulse counting · 2 × 4–20 mA · 2 × 0–10 V · 2 × PT100 | 1 × RS485 · up to 15 Modbus commands per uplink cycle |
| Outputs | — (switching is the MacSet controller range) | 2 × SPDT relays, 3 A | — |
| Power | 19 Ah Li-SOCl₂ battery or 9–36 V DC | 9–36 V DC, no battery | 7–24 V DC, no battery (RS485-LB/BL variants carry an 8,500 mAh cell) |
| Battery life | About 2 years at 5-minute and 7+ years at hourly reporting on the battery version | Mains powered | Mains powered |
| Networks | LoRaWAN · MacTalk device-to-device · Bluetooth local versions | LoRaWAN or 4G LTE models | LoRaWAN |
| LoRaWAN | v1.0.4 · Class A, Class C via the app · OTAA | LoRaWAN; class not on the page checked | Class A and Class C, default Class C · OTAA |
| Enclosure | Glass-filled nylon · IP65, IP67 optional · −40 to +80 °C | IP30 metal housing for indoor use | Not stated on the page checked |
| Bands | IN865 · RU864 · EU868 · US915 · AU915 | Global frequency plans | CN470 · EU433 · KR920 · US915 · EU868 · AS923 · AU915 · IN865 · RU864 · MA869 |
| Configuration | Maya app over Bluetooth · downlink | Milesight configuration tool | AT commands · downlink · RS485 configure tool |
| Designed and made in | Designed and manufactured in Pune, India | Milesight, Xiamen, China | Dragino, Shenzhen, China |
Figures for the other products are taken from their manufacturers' published datasheets and product pages, checked on 7 October 2026, and may change; check the linked sources before you order. Milesight, Dragino, SenseCAP and RAK are trademarks of their respective owners.
Where each fits
What the table means for your site
Where the MacSync LX1 fits
Meters and transmitters with no supply nearby: water networks, farms, utility assets and tank farms, where a battery datalogger with 4–20 mA and 0–10 V inputs and an IP65 outdoor housing matters. The DC version serves panels, and the MacTalk variant links devices without a gateway. Indian manufacture, WPC compliance and support from Pune come with it.
Where the Milesight UC300 fits
Indoor panels with power that need relays, pulse-counting digital inputs, PT100 inputs and RS232 as well as RS485, with a 4G model for sites without a gateway. Its IP30 metal housing is for inside a cabinet, not outdoors.
Where the Dragino RS485-LN fits
A low-cost mains-powered bridge for a powered RS485 device, with Class C by default for fast downlinks and a wide band list. Configuration is by AT commands and a configure tool.
Get a quote
Need a quote for the MacSync LX1?
Tell us how many you need and where they are going. A product engineer replies within one working day with availability, lead time and the right variant, and will tell you honestly if another unit fits your site better.
- Reply within one working day
- Designed and built in Pune, India
- WPC compliant, RoHS conformant
Questions
Choosing between them
The MacSync LX1 battery version runs for years on a 19 Ah cell, which is what makes remote meters and transmitters practical. The UC300 and RS485-LN are mains-powered; Dragino's RS485-LB and RS485-BL variants add an 8,500 mAh battery for a comparable job.
The Milesight UC300 carries two 3 A relays. Macnman keeps acquisition and control separate: the LX1 reads, and the MacSet LX1 controller with two 16 A relays switches, so each device is sized for its job.
The MacSync LX1 reads two 4–20 mA and two 0–10 V inputs in place of RS485, and the UC300 has two of each plus PT100 inputs. The RS485-LN is RS485 only.
Sources
Other comparisons
Let‘s make it easy - reach out now!
Let’s bring it to life!
Let‘s Make it Easy
Reach Out Now
We are always ready
to help and
answer your
questions
Call
+91 7972856163
+91 9096830856
Location
Office-15 Bibwewadi, Pune, Maharashtra 411037
Get in Touch
Define your goals and all to value your time
Use of this website and purchase of Macnman products are subject to our Terms and Conditions.