Compared

LoRaWAN Ultrasonic Level Sensors Compared: MacRay LUS X1 vs Milesight EM310-UDL vs Dragino DDS45-LB vs Milesight EM500-UDL

Four non-contact LoRaWAN level sensors for tanks, sumps, drains, silos and bins, for anyone weighing an alternative to the EM310-UDL, the EM500-UDL or the Dragino DDS45-LB (the LDDS45/LDDS75 line). Three share the 3 to 450 cm class; the differences are operating range, alerts, configuration, gateway-free options and where the hardware and the support come from.

Macnman product on this page: MacRay LUS X1

Side by side

The published figures

Every value is as each manufacturer publishes it, checked on 11 October 2026. Where a page does not state a figure, the cell says so.

CompareMacnman MacRay LUS X1Milesight EM310-UDLDragino DDS45-LBMilesight EM500-UDL
Measuring range3 to 450 cm · 3 cm blind zone3 to 450 cm · blind zone described as ultra-short, no figure3 to 450 cm (flat object); below 3 cm reads zero0.3–5 m or 0.5–10 m (W models) · 0.25–5 m or 0.25–10 m (C models)
Accuracy and resolution0.1 cm resolution · 100 ms response; accuracy not stated on the datasheet±(1 + 0.3 % × distance) cm · 1 mm±(1 + 0.3 % × distance) cm · resolution not stated±1 % of full scale (W) · ±(1 + 0.3 % × distance) cm (C) · 1 mm
Beam60° sensing angle, 40 kHzDual beams; angle not stated60° measure angleNot stated on the page checked
Battery8 Ah Li-SOCl₂ · about 1 / 2 / 3+ years at 5 / 15 / 60-minute reports2 × 3,500 mAh ER17505 · ≥10 years at 10-minute reports plus 20 triggers a day8,500 mAh Li-SOCl₂ · up to 5 years, conditions not stated19,000 mAh ER34615 · 10 years at 10-minute reports, 25 °C, lab conditions
EnclosureIP67 head, IP55 body · −40 to +80 °C · 96 × 96 × 28 mm · ~110 gIP67 · −15 to +60 °C · 111 × 62 × 40 mm · 168 gIP66 · −40 to +85 °C in one section, −15 to +60 °C in another · size not statedIP67 · −30 to +65 °C (W), −15 to +60 °C (C) · 156 × 71 × 69.5 mm · ~365 g
LoRaWANv1.0.4 · Class A, Class C via the app · OTAAClass A · OTAA and ABPv1.0.3 · Class AClass A · OTAA and ABP
BandsIN865 · RU864 · EU868 · US915 · AU915CN470 · IN865 · RU864 · EU868 · US915 · AU915 · KR920 · AS923CN470 · EU433 · KR920 · US915 · EU868 · AS923 · AU915 · IN865CN470 · IN865 · RU864 · EU868 · US915 · AU915 · KR920 · AS923
IN865 for IndiaStandard, WPC compliantIn the band listIn the band listIn the band list
AlertsLevel threshold with event uplink; samplingThreshold and tilt statusInterrupt pin; no level alarm describedThreshold and change alarms
Temperature compensationNot stated on the datasheetNot stated on the page checkedPerformed internally, per the manualNot stated on the page checked
Readings kept on the deviceNot stated on the datasheetNot stated on the page checkedDatalog sent after the network returns1,000 entries, with retransmission
ConfigurationMaya app over Bluetooth · downlinkNFC appAT commands over Bluetooth or UART · downlinkNFC app · USB-C · downlink
Gateway-free optionMacTalk variant to a MacSet controller; Bluetooth variant———
ManufacturerMacnman, Pune, IndiaMilesight, Xiamen, ChinaDragino, Shenzhen, ChinaMilesight, Xiamen, China

Figures for the other products are taken from their manufacturers' published product pages and documentation, checked on 11 October 2026, and may change; check the linked sources before you order. Milesight and Dragino are trademarks of their respective owners.

Where each fits

What the table means for your site

Where the MacRay LUS X1 fits

Tanks, sumps, drains and bins across an Indian site where the sensor must survive a hot tank top (rated to +80 °C), send an alert on a level limit, be set up from a phone by a facilities crew, and come from a maker in India with WPC-compliant IN865 hardware and support in Indian time. The MacTalk variant turns a tank and a MacSet pump controller into a wireless float switch with no gateway.

Where the Milesight EM310-UDL fits

The same 3 to 450 cm class in a compact IP67 unit with a stated accuracy formula, a tilt sensor and a long battery claim on two small cells, set up over NFC. Its operating range stops at +60 °C and there is no level alarm beyond the threshold rule.

Where the Dragino DDS45-LB fits

The low-cost route to a 3 to 450 cm LoRaWAN reading with internal temperature compensation and a datalog, configured by AT commands over Bluetooth or a cable. Its page states two different operating ranges and no dimensions, and it has no level alarm, only an interrupt pin.

Where the Milesight EM500-UDL fits

Deeper vessels: 5 or 10 m models on a 19 Ah cell with a 10-year lab claim, threshold and change alarms and 1,000 stored entries. It is larger and heavier, and its operating range stops at +65 °C.

Get a quote

Need a quote for the MacRay LUS X1?

Tell us how many you need and where they are going. A product engineer replies within one working day with availability, lead time and the right variant, and will tell you honestly if another unit fits your site better.

  • Reply within one working day
  • Designed and built in Pune, India
  • WPC compliant, RoHS conformant

Questions

Choosing between them

The MacRay LUS X1, the Milesight EM310-UDL and the Dragino DDS45-LB all cover 3 to 450 cm; the Dragino DDS75-LB (the former LDDS75) covers 28 to 750 cm and the Milesight EM500-UDL 5 or 10 m depending on the model. For a tank deeper than about 4.5 m, look at the EM500-UDL or the DDS75-LB class.

Milesight and Dragino publish a formula, ±(1 cm + 0.3 % of the distance) for the EM310-UDL, the DDS45-LB and the EM500-UDL C models, and ±1 % of full scale for the EM500-UDL W models. The MacRay LUS X1 datasheet states 0.1 cm resolution and does not publish an accuracy figure; ask Macnman for the figure for your tank and surface before comparing on accuracy.

The MacRay LUS X1 is rated from −40 to +80 °C. The EM310-UDL stops at +60 °C, the EM500-UDL at +65 °C (W models), and the DDS45-LB page gives both −40 to +85 °C and −15 to +60 °C. Heat also shortens any lithium cell's life, so a shaded mounting helps every one of them.

Each maker states life for its own conditions. Macnman quotes about 1 year at 5-minute, 2 years at 15-minute and 3+ years at hourly reports on an 8 Ah cell; Milesight quotes 10 years at 10-minute reports under laboratory conditions on a 19 Ah cell (EM500-UDL) or two 3,500 mAh cells (EM310-UDL); Dragino quotes up to 5 years without conditions. Compare at the interval and spreading factor you will run, and use the free battery calculator on this site.

Only the MacRay LUS X1, through its MacTalk variant, which sends the level straight to a MacSet controller whose relays switch the pump. The others report to a network server, which then needs its own rules and a controller on the network to act.

The MacRay LUS X1 is WPC compliant for the IN865 band and is manufactured in Pune. The other three list IN865 as a band; check the current compliance status of imported units with their Indian distributor.

Got an IoT idea?

Let’s bring it to life!

flag image

WPC compliant · RoHS · a product engineer replies within one working day

Let‘s Make it Easy

Reach Out Now

Icon

Contact to Sales

Talk to our friendly team

chat@macnman.com
Icon

Call Us

24 X 7 Always On

+91 7972856163
Icon

Contact to Support

We are here to help

support@macnman.com
Icon

Visit Us

Visit our office HQ

View on Google Map

Socials

Use of this website and purchase of Macnman products are subject to our Terms and Conditions.