Compared

LoRaWAN Gas Sensors Compared: MacSync LH2S X1 and L Odor X2 vs Milesight GS301 vs Zonewu vs Daviteq WSLRW-G4 vs Atomsenses AS-108

Five LoRaWAN electrochemical gas monitors for hydrogen sulphide and ammonia, for anyone weighing an alternative to the GS301, a Zonewu or Atomsenses node or a Daviteq build-to-order sensor. The differences are the range each cell covers, whether accuracy is stated at all, cell life, battery against DC, indoor against outdoor enclosures, a local buzzer against platform alerts, IN865 as standard and where the hardware and the support come from. None of the five is a certified safety detector.

Macnman product on this page: MacSync LH2S X1 / L Odor X2

Side by side

The published figures

Every value is as each manufacturer publishes it, checked on 25 October 2026. Where a page does not state a figure, the cell says so.

CompareMacnman MacSync LH2S X1 / L Odor X2Milesight GS301Zonewu LoRaWAN H₂SDaviteq WSLRW-G4Atomsenses AS-108
Gases and rangeH₂S 0–100 ppm; NH₃ 0–100 ppm on the L Odor X2; oxygen 0–30 % and ethylene 0–100 ppm on sister nodesNH₃ 0–10 ppm, H₂S 0–5 ppm, temperature, humidityH₂S 0–10 ppm, temperature, humidityCO, NO, NO₂, H₂S, NH₃, O₂, O₃, SO₂, Cl₂, HCHO options; ranges not on the pageH₂S 0–100 ppm, temperature, humidity
Resolution0.1 ppm H₂S · 0.5 ppm NH₃0.001 ppm H₂S · 0.01 ppm NH₃0.01 ppmNot on the page0.01 ppm
Stated accuracyNot stated; repeatability under 2 % (H₂S), under 10 % (NH₃)±5 % FSNot statedNot on the pageUnder ±3 %
Cell life and calibration2 years; factory calibrated; field interval not statedOver 3 years; drift under 1 % per monthUnder 2 years; recalibrate every 6–12 months (maker's FAQ)Not on the pageNot on the page
Power19 Ah: about 2 / 4 / 7+ years at 5 / 15 / 60-minute reports; or 9–36 V DCFour 4,000 mAh cells, about 3 years at 10-minute reports5–28 V DC only, no batteryTwo AA cells, 5–10 years claimedThree ER14505 or four ER18505 cells
Enclosure and temperatureIP65, IP67 option; −40 to +80 °C; glass-filled nylonIP30; −40 to 55 °C, recommended below 35 °C120 g; cell −20 to 50 °C; IP not statedNot on the pageIP30
Local alarmNone; alerts to the platform or a MacSet controllerBuzzer and traffic-light LEDNot statedNot statedNot stated
Radio and IN865LoRaWAN 1.0.4, Class A, Class C from the app; IN865 standard; MacTalk device to deviceClass A, OTAA and ABP; IN865 among eight plans; NFCLoRaWAN 1.0.3, Class C default; IN865 among eight plansLoRaWAN; IN865 listed on the optical oxygen modelClass C, OTAA and ABP; IN865 among eight plans
PositioningOutdoor and industrial: STPs, sewers, sheds, yards, storesIndoor washrooms and roomsIndoor and industrial, DC poweredBuilt to orderIndoor; 'between personal detectors and fixed systems'
Designed and made inPune, India; WPC compliant, RoHSChinaChinaVietnamChina

Figures for the other products are taken from their manufacturers' published pages, checked on 25 October 2026, and may change; check the linked sources before you order. Milesight, Zonewu, Daviteq and Atomsenses are trademarks of their respective owners.

Where each fits

What the table means for your site

Where the MacSync gas sensors fit

Outdoor and industrial points: STP works, sewer chambers, landfill fence lines, livestock sheds, cylinder stores and ripening rooms, with 0–100 ppm cells, an IP65 enclosure with an IP67 option rated −40 to +80 °C, a 19 Ah battery or 9–36 V DC, Class C and MacTalk from a phone, IN865 as standard with WPC compliance, made and supported in Pune. The datasheets state no accuracy figure, no cross-sensitivity and no recalibration interval, and this comparison says so.

Where the Milesight GS301 fits

Indoor washrooms and rooms: low ranges (NH₃ to 10 ppm, H₂S to 5 ppm) at fine resolution with ±5 % FS stated, a buzzer and traffic-light LED, a long-life cell, IP30 and a recommendation to run below 35 °C.

Where the Zonewu node fits

DC-powered indoor or industrial points with a 0–10 ppm H₂S cell, Class C by default and a candid FAQ on recalibration every 6–12 months; no battery variant and no ingress rating on the page.

Where the Daviteq WSLRW-G4 fits

A build-to-order multi-gas node with ten cell options and a long claimed life on two AA cells; ranges and certificates are not on the public page.

Where the Atomsenses AS-108 fits

An indoor IP30 H₂S node with a 0–100 ppm cell at 0.01 ppm resolution and a stated accuracy, positioned between personal detectors and fixed systems, on IN865 among eight plans.

Get a quote

Need a quote for the MacSync LH2S X1 / L Odor X2?

Tell us how many you need and where they are going. A product engineer replies within one working day with availability, lead time and the right variant, and will tell you honestly if another unit fits your site better.

  • Reply within one working day
  • Designed and built in Pune, India
  • WPC compliant, RoHS conformant

Questions

Choosing between them

None. All five are monitoring nodes that report over LoRaWAN on an interval; a certified fixed detector or a personal monitor remains where law, an entry permit or a safety case requires one.

The MacSync gas sensors, designed and manufactured in Pune, with WPC compliance and RoHS on their datasheets and IN865 as the shipped plan. Milesight, Zonewu and Atomsenses list IN865 among their plans; Daviteq lists it on its optical oxygen model.

The MacSync sensors (IP65, IP67 option, 19 Ah battery) and, on their pages, no other: the GS301 and AS-108 are IP30 indoor nodes, the Zonewu node is DC powered and Daviteq's enclosure rating is not published for the G4.

Got an IoT idea?

Let’s bring it to life!

flag image

WPC compliant · RoHS · a product engineer replies within one working day

Let‘s Make it Easy

Reach Out Now

Icon

Contact to Sales

Talk to our friendly team

chat@macnman.com
Icon

Call Us

24 X 7 Always On

+91 7972856163
Icon

Contact to Support

We are here to help

support@macnman.com
Icon

Visit Us

Visit our office HQ

View on Google Map

Socials