MacSync L Odor X2 LoRaWAN® NH₃ & H₂S Odor Monitoring Sensor Datasheet
Product Overview
MacSync LODS X2 LoRaWAN® Odor Monitoring Sensor is a high-precision industrial odor monitoring solution designed for continuous real-time NH₃ (Ammonia) and H₂S (Hydrogen Sulfide) concentration monitoring across wastewater treatment plants, sewage infrastructure, industrial facilities, chemical factories, livestock farms, landfills, smart cities, and environmental monitoring deployments.
Built using ultra-low-power electronics and long-range LoRaWAN® wireless technology, the sensor enables reliable remote odor monitoring without requiring complex wired infrastructure. The device continuously measures NH₃ and H₂S gas concentrations to help organizations detect odor pollution, monitor hazardous gas exposure, improve worker safety, maintain environmental compliance, and reduce public odor complaints.
The LoRaWAN Odor Sensor is engineered for Industrial IoT deployments where long battery life, wide-area coverage, secure wireless communication, and centralized cloud monitoring are critical. It is ideal for STP & WWTP plants, sludge treatment facilities, pumping stations, waste management infrastructure, smart city odor analytics, industrial safety systems, and environmental air-quality monitoring.
With configurable uplink intervals, threshold-based odor alerts, BLE configuration via the Macnman Maya App, and seamless integration with LoRaWAN® gateways and cloud IoT platforms, the MacSync LODS X2 delivers scalable odor analytics for Industry 4.0 and environmental monitoring deployments.
Its rugged industrial enclosure, IP65 protection, low-power battery operation, and AES-encrypted wireless communication make it suitable for harsh indoor and outdoor industrial deployments requiring reliable wireless odor monitoring.
Download Center
Download the PDF version of the datasheet.
Click here to view the decoders for MacSync L Odor X2
Key Features
High-Precision NH₃ & H₂S Monitoring Simultaneous real-time monitoring of ammonia (NH₃) and hydrogen sulfide (H₂S) concentrations for industrial odor analytics and environmental compliance.
LoRaWAN® Wireless Odor Monitoring Long-range wireless communication enables reliable odor monitoring across wastewater plants, industrial facilities, smart cities, and remote infrastructure.
Industrial Odor Pollution Detection Detect odor-causing gases near STP, WWTP, sludge handling systems, drainage infrastructure, and waste management facilities.
Real-Time Threshold-Based Alerts Configurable NH₃ and H₂S threshold alerts for immediate odor event notification and rapid response.
Ultra-Low-Power Architecture Optimized low-power electronics enable long-term battery-powered wireless odor monitoring deployments.
Smart City Odor Analytics Ideal for smart city environmental monitoring and public odor complaint management systems.
Industrial-Grade IP65 Enclosure Rugged enclosure designed for harsh industrial, wastewater, chemical, and outdoor environmental monitoring deployments.
BLE Configuration via Maya App Configure, diagnose, and manage the LoRaWAN® odor sensor wirelessly using the Macnman Maya mobile application.
Cloud, SCADA & Industrial IoT Integration Integrates with LoRaWAN® gateways, MQTT servers, SCADA systems, and cloud monitoring dashboards.
Secure AES-Encrypted Communication AES-128 encrypted wireless communication ensures secure and reliable odor monitoring data transmission.
Applications
Wastewater Treatment Plant Odor Monitoring Continuous NH₃ and H₂S odor monitoring across STP, WWTP, sludge handling systems, aeration tanks, and sewage treatment infrastructure.
Smart City Odor Monitoring Deploy LoRaWAN® odor sensors near drainage lines, sewage networks, waste collection zones, and urban odor hotspots to reduce public odor complaints.
Industrial Odor Pollution Monitoring Monitor odor-causing gases across chemical factories, process industries, wastewater facilities, and industrial production environments.
Landfill & Waste Management Monitoring Detect ammonia and hydrogen sulfide emissions across landfill sites, garbage transfer stations, and municipal waste management facilities.
Livestock & Poultry Farm Monitoring Real-time NH₃ monitoring to improve ventilation management, animal safety, and environmental compliance in livestock operations.
Industrial Worker Safety Monitoring Detect hazardous NH₃ and H₂S gas exposure in confined industrial environments to improve worker safety and operational visibility.
Sewer Network & Pumping Station Monitoring Monitor toxic gas accumulation and odor emissions across underground sewage networks, pumping stations, and drainage infrastructure.
Environmental Compliance Monitoring Support industrial environmental compliance and air-quality monitoring using long-range LoRaWAN® odor monitoring infrastructure.
Industrial IoT Odor Analytics Integrate odor monitoring data into SCADA systems, cloud dashboards, MQTT servers, and Industrial IoT analytics platforms.
Chemical Storage & Hazardous Gas Monitoring Monitor NH₃ and H₂S concentration levels near chemical storage areas, gas handling systems, and industrial processing zones.
Technical Specifications
MacSync L Odor X2 Variants
| SKU | Variant Name | Gas Monitoring | Power Source | Communication | Ideal For |
|---|---|---|---|---|---|
| 8516 | MacSync-L-Odor-BS-X2 | NH₃ + H₂S | Battery (19 Ah) | LoRaWAN® | Remote quantitative odor monitoring for STP, WWTP, landfills, smart cities, and environmental compliance |
| 8517 | MacSync-L-Odor-PS-X2 | NH₃ + H₂S | 9–36 V DC | LoRaWAN® | Continuous industrial odor monitoring with external power for wastewater and process industries |
| 8518 | MacSync-M-Odor-BS-X2 | NH₃ + H₂S | Battery (19 Ah) | MacTalk | Battery-operated MacTalk deployments for remote quantitative odor monitoring |
| 8519 | MacSync-M-Odor-PS-X2 | NH₃ + H₂S | 9–36 V DC | MacTalk | MacTalk-based industrial odor monitoring with continuous external power |
| 8520 | MacSync-B-Odor-BS-X2 | NH₃ + H₂S | Battery (19 Ah) | BLE | Local quantitative odor monitoring, commissioning, and diagnostics using BLE connectivity |
What's in the Box?
Make sure the box contains the following items before installation.
- MacSync L Odor X2 Sensor
- Mounting Clip
- User Manual
- Warranty Card
- IP68 Cable Extender *
- Mounting Screws
- Power Adapter *
Accessories marked with (*) must be purchased separately and may not be included in the box.
MacSync L Odor X2 Dimensions
The MacSync L Odor X2 features a compact industrial-grade enclosure with overall dimensions of 152 mm × 62 mm × 43 mm, enabling easy wall and pole mounting across wastewater treatment plants, industrial facilities, sewage infrastructure, landfill monitoring deployments, and environmental odor monitoring applications.

Frequently Asked Questions
What is the MacSync L Odor X2 used for?
MacSync L Odor X2 is an industrial LoRaWAN odor sensor with NH3 and H2S measurement for wastewater plants, smart cities and environmental compliance. Typical applications include Wastewater Treatment Plant Odor Monitoring, Smart City Odor Monitoring, Industrial Odor Pollution Monitoring, Landfill & Waste Management Monitoring, Livestock & Poultry Farm Monitoring and Industrial Worker Safety Monitoring.
What does the MacSync L Odor X2 measure, and how accurately?
Measurement specifications of the MacSync L Odor X2:
- NH₃: range 0 – 100 ppm, resolution 0.5 ppm.
- H₂S: range 0 – 100 ppm, resolution 0.1 ppm.
Which LoRaWAN frequency bands and network servers does the MacSync L Odor X2 support?
The MacSync L Odor X2 supports LoRaWAN® (v1.0.4) and the Macnman MacTalk Protocol on the IN865 / RU864 / EU868 / US915 / AU915 / KR920 / AS923 frequency bands. It joins the network by OTAA activation. It runs as Class A by default and can be set to Class C in the Maya app. Supported network servers: Private LNS, ChirpStack, TTN, MQTT, Orbiwise, Netmore, and on-premise industrial IoT deployments.
How long does the MacSync L Odor X2 battery last?
The battery-operated MacSync L Odor X2 runs on a 19 Ah industrial-grade Li-SOCl₂ cell. Estimated battery life is ~2 years at a 5-minute reporting interval, ~4 years at a 15-minute reporting interval and ~7+ years at a 60-minute reporting interval. A power-operated version runs from 9 ~ 36 V DC (External Supply).
What is the IP rating and operating temperature of the MacSync L Odor X2?
The MacSync L Odor X2 has an ingress protection rating of IP65 standard (IP67 optional variant) and an operating temperature range of -40°C to +80°C. Operating humidity: 0% ~ 100% RH (non-condensing). Mounting options: Pole Mount / Wall Mount.
How is the MacSync L Odor X2 configured?
The MacSync L Odor X2 is configured with the Macnman Maya Android app over Bluetooth Low Energy (BLE). Settings can also be changed remotely with over-the-air downlink commands.
What is included in the box with the MacSync L Odor X2?
The box contains: MacSync L Odor X2 Sensor, Mounting Clip, User Manual, Warranty Card and Mounting Screws. IP68 Cable Extender and Power Adapter are optional and may need to be purchased separately.
Related Products and Resources
- Setup guide: Common LoRaWAN sensor settings in the Maya app
- Compatible LoRaWAN gateways: MacLink Gen-2 industrial outdoor LoRaWAN gateway and Setu LX Series indoor LoRaWAN gateway
- Related datasheets: MacSync-WGSX2 Wi-Fi H2S and NH3 gas sensor, MacSync LOXGS X1 LoRaWAN oxygen sensor, MacSync LC2H4 X1 LoRaWAN ethylene sensor, MacSync L Odor X1 LoRaWAN qualitative odor sensor
- Help: Warranty terms and conditions and contact Macnman support