**MacSync-W-Odor-X1** is a qualitative **Wi‑Fi–based odor monitoring sensor** designed to detect, track, and trend **odor intensity levels** in industrial, municipal, and commercial environments where reliable IP connectivity is available. Instead of measuring individual gas concentrations in ppm, the device evaluates overall odor presence and strength, making it ideal for applications where **nuisance odor detection, early warning, and compliance monitoring** are critical.

Built on advanced sensing elements and intelligent signal processing, MacSync-W-Odor-X1 converts complex odor signatures into a **simple odor index / odor level**, enabling easy interpretation and actionable insights. This qualitative approach allows operators to identify odor spikes, persistent odor patterns, and abnormal events without requiring gas‑specific calibration or complex analysis.

Designed for continuous operation in real‑world environments, the device features an **industrial‑grade, ingress‑protected enclosure** suitable for **sewage treatment plants (STP), wastewater facilities (WWTP), landfills, waste processing units, factories, commercial buildings, and indoor utility areas** within Wi‑Fi coverage.

MacSync-W-Odor-X1 transmits odor data securely over **standard Wi‑Fi networks (2.4 GHz / 5 GHz)** directly to **on‑premise servers, dashboards, SCADA systems, or cloud platforms** using industry‑standard protocols such as **MQTT, HTTP, and HTTPS**—without the need for gateways or long‑range wireless infrastructure. **Local BLE‑based configuration via the Macnman Maya App** enables fast provisioning, diagnostics, and maintenance.

Whether used for regulatory reporting, community odor complaint management, or proactive operational control, MacSync-W-Odor-X1 delivers a **reliable, low‑maintenance, and data‑driven Wi‑Fi odor monitoring solution**, transforming subjective smell complaints into measurable intelligence.

| ![MacSync LTS X1 LoRaWAN temperature humidity sensor front view for industrial environmental monitoring](/img/lorawan/sensors/macsync/macsync-lts-x1-industrial-environmental-sensor-side-view.webp) | ![MacSync LTS X1 wireless LoRaWAN temperature humidity sensor mounted installation view](/img/lorawan/sensors/macsync/macsync-lts-x1-lorawan-temperature-humidity-sensor-front-view.webp) |
|--------------------------------|--------------------------------|
| ![Industrial LoRaWAN environmental sensor side profile with rugged IP65 enclosure](/img/lorawan/sensors/macsync/macsync-lts-x1-smart-agriculture-temperature-sensor.webp) | ![MacSync LTS X1 smart agriculture LoRaWAN temperature and humidity monitoring sensor](/img/lorawan/sensors/macsync/macsync-lts-x1-wireless-temperature-humidity-sensor-mounted.webp) |

<div class="faint-line"></div>

## Download Center

<div className="icon-card-grid">
  <a href="https://www.macnman.com/downloads/MacSync-LS7.pdf" 
  className="icon-card">
    <div className="icon">📂</div>  
    <div>
      <strong>[Download Datasheet](https://www.macnman.com/downloads/MacSync-LS7.pdf)</strong>
      <p> Download the PDF Version of the Datasheet
.</p>
    </div>
  </a>
  <a href="https://github.com/MacnMan/LoRa_Module_SDK/tree/main/SDK/LoRaWAN_AT_Slave" 
  className="icon-card">
    <div className="icon">📝</div>
    <div>
      <strong>Decoders</strong>
      <p>Click here to view the decoders for MacSync-W-Odor-X1</p>
    </div>
  </a>
</div>

<div class="faint-line"></div>

## Key Features

<div className="reusable-feature-grid">

  <div className="reusable-feature-card">
    <strong>Qualitative Odor Intensity Detection</strong>
    Measures overall odor presence and strength using a qualitative odor index, ideal for nuisance odor monitoring without ppm-level gas complexity.
  </div>

  <div className="reusable-feature-card">
    <strong>Odor Index & Trend Analysis</strong>
    Converts complex odor signatures into a simple odor level for long-term trend analysis and correlation with operational events.
  </div>

  <div className="reusable-feature-card">
    <strong>Early Warning & Threshold Alerts</strong>
    Configurable odor thresholds trigger alerts for sudden odor spikes, persistent odor conditions, and abnormal events.
  </div>

  <div className="reusable-feature-card">
    <strong>Wi‑Fi Based Connectivity</strong>
    Direct odor data transmission over standard Wi‑Fi networks (2.4 GHz / 5 GHz) without gateways or long‑range infrastructure.
  </div>

  <div className="reusable-feature-card">
    <strong>Industrial‑Grade & Outdoor‑Ready Design</strong>
    Rugged, ingress‑protected enclosure suitable for STP, WWTP, landfills, waste processing plants, factories, and utility areas within Wi‑Fi coverage.
  </div>

  <div className="reusable-feature-card">
    <strong>No Gas‑Specific Calibration Required</strong>
    Qualitative sensing eliminates the need for individual gas calibration, reducing maintenance effort and operational complexity.
  </div>

  <div className="reusable-feature-card">
    <strong>Secure IP‑Based Communication</strong>
    WPA2/WPA3 Wi‑Fi security with TLS‑encrypted data transmission ensures safe and reliable odor data delivery.
  </div>

  <div className="reusable-feature-card">
    <strong>Flexible Reporting Modes</strong>
    Supports time‑based, threshold‑based, and event‑driven reporting to balance responsiveness and power consumption.
  </div>

  <div className="reusable-feature-card">
    <strong>BLE Configuration via Maya App</strong>
    Local device configuration, diagnostics, and maintenance using the Macnman Maya mobile application.
  </div>

  <div className="reusable-feature-card">
    <strong>On‑Prem & Cloud Integration Ready</strong>
    Compatible with on‑premise servers, dashboards, SCADA systems, and cloud platforms using MQTT, HTTP, and HTTPS.
  </div>

</div>
<div class="faint-line"></div>

## Suited Applications

<div className="reusable-feature-grid">

  <div className="reusable-feature-card">
    <strong>Sewage Treatment Plants (STP)</strong>
    Continuous monitoring of nuisance odors from inlet chambers, aeration tanks, and sludge handling areas within Wi‑Fi‑enabled facilities.
  </div>

  <div className="reusable-feature-card">
    <strong>Wastewater Treatment Plants (WWTP)</strong>
    Odor intensity tracking across treatment processes to detect abnormal events, process inefficiencies, and odor spikes.
  </div>

  <div className="reusable-feature-card">
    <strong>Landfills & Waste Disposal Sites</strong>
    Qualitative odor monitoring to identify emission trends and manage odor impact within site premises.
  </div>

  <div className="reusable-feature-card">
    <strong>Solid Waste & Composting Facilities</strong>
    Odor level monitoring to identify high‑odor zones and optimize waste handling and composting operations.
  </div>

  <div className="reusable-feature-card">
    <strong>Industrial Manufacturing Plants</strong>
    Odor detection around chemical processing, food processing, paper mills, and industrial production areas.
  </div>

  <div className="reusable-feature-card">
    <strong>Commercial Buildings & Utility Areas</strong>
    Odor monitoring in basements, utility rooms, garbage areas, and common service zones inside buildings.
  </div>

  <div className="reusable-feature-card">
    <strong>Environmental Compliance & Reporting</strong>
    Supports regulatory monitoring programs and data‑driven reporting for odor‑related compliance requirements.
  </div>

  <div className="reusable-feature-card">
    <strong>Community Odor Complaint Correlation</strong>
    Provides objective odor data to correlate citizen complaints with actual odor events and operational conditions.
  </div>

</div>

<div class="faint-line"></div>

## Technical Specification

<div className="spec-block">
  <div className="spec-block-title">
    General <br /> Specifications
  </div>
  <div className="spec-block-details">
    <p className="label">Part Order Number</p>
    <p className="value">MacSync-W-Odor-X1</p>
    <br />
    <p className="label">Product Brand</p>
    <p className="value">Macnman Technologies Pvt Ltd</p>
  </div>
</div>

<div class="faint-line"></div>

<div className="spec-block">
  <div className="spec-block-title">
    Temperature <br /> Measurement
  </div>
  <div className="spec-block-details">
    <p className="label">Range</p>
    <p className="value">-30°C to +70°C</p>
    <br />
    <p className="label">Accuracy</p>
    <p className="value">0°C to +70°C: ±0.3°C &amp; -30°C to 0°C: ±0.6°C</p>
    <br />
    <p className="label">Resolution</p>
    <p className="value">0.1°C</p>
    <br />
    <p className="label">Calibration</p>
    <p className="value">Factory calibrated</p>
    <br />
    <p className="label">Probe Options</p>
    <p className="value">Internal &amp; External Both Options</p>
  </div>
</div>

<div class="faint-line"></div>

<div className="spec-block">
  <div className="spec-block-title">
    Humidity <br /> Measurement
  </div>
  <div className="spec-block-details">
    <p className="label">Range</p>
    <p className="value">0% to 100% RH</p>
    <br />
    <p className="label">Accuracy</p>
    <p className="value">10% to 90% RH: ±3% RH &amp; &lt;10% or &gt;90% RH: ±5% RH</p>
    <br />
    <p className="label">Resolution</p>
    <p className="value">0.5% RH</p>
    <br />
    <p className="label">Calibration</p>
    <p className="value">Factory calibrated</p>
  </div>
</div>

<div class="faint-line"></div>

<div className="spec-block">
  <div className="spec-block-title">
    Pressure <br /> Measurement
  </div>
  <div className="spec-block-details">
    <p className="label">Range</p>
    <p className="value">300 hPa to 1100 hPa</p>
    <br />
    <p className="label">Accuracy</p>
    <p className="value">±1.0 hPa (typical at 25°C, 300–1100 hPa)</p>
    <br />
    <p className="label">Resolution</p>
    <p className="value">0.1 hPa</p>
    <br />
    <p className="label">Long‑Term Stability</p>
    <p className="value">≤ ±1 hPa/year</p>
    <br />
    <p className="label">Calibration</p>
    <p className="value">Factory calibrated</p>
  </div>
</div>

<div class="faint-line"></div>

<div className="spec-block">
  <div className="spec-block-title">
    NH3 <br /> Measurement
  </div>
  <div className="spec-block-details">
    <p className="label">Gas Detected</p>
    <p className="value">Ammonia (NH₃)</p>
    <br />
    <p className="label">Detection Range</p>
    <p className="value">1 to 300 ppm</p>
    <br />
    <p className="label">Sensitivity</p>
    <p className="value">R₀ (in air) / Rs (in 50 ppm NH₃) ≥ 3</p>
    <br />
    <p className="label">Measurement Type</p>
    <p className="value">Gas concentration (ppm)</p>
    <br />
    <p className="label">Operating Temperature</p>
    <p className="value">-10°C to +50°C</p>
    <br />
    <p className="label">Operating Humidity</p>
    <p className="value">15% to 90% RH (non-condensing)</p>
    <br />
    <p className="label">Expected Lifespan</p>
    <p className="value">≥ 5 years (in air)</p>
    <br />
    <p className="label">Calibration</p>
    <p className="value">Factory calibrated</p>
  </div>
</div>

<div class="faint-line"></div>

<div className="spec-block">
  <div className="spec-block-title">
    H2S <br /> Measurement
  </div>
  <div className="spec-block-details">
    <p className="label">Gas Detected</p>
    <p className="value">Hydrogen Sulfide (H₂S), Benzene</p>
    <br />
    <p className="label">Detection Range</p>
    <p className="value">0.5 to 50 ppm</p>
    <br />
    <p className="label">Sensitivity</p>
    <p className="value">R₀ (in air) / Rs (in 50 ppm H₂S) ≥ 3</p>
    <br />
    <p className="label">Measurement Type</p>
    <p className="value">Gas concentration (ppm)</p>
    <br />
    <p className="label">Operating Temperature</p>
    <p className="value">-10°C to +50°C</p>
    <br />
    <p className="label">Operating Humidity</p>
    <p className="value">15% to 90% RH (non-condensing)</p>
    <br />
    <p className="label">Expected Lifespan</p>
    <p className="value">≥ 5 years (in air)</p>
    <br />
    <p className="label">Calibration</p>
    <p className="value">Factory calibrated</p>
  </div>
</div>

<div class="faint-line"></div>

<div className="spec-block">
  <div className="spec-block-title">
    Wireless <br /> Communication
  </div>
  <div className="spec-block-details">
    <p className="label">Wi‑Fi Standards</p>
    <p className="value">IEEE 802.11 b/g/n/ac</p>
    <br />

    <p className="label">Frequency Bands</p>
    <p className="value">2.4 GHz & 5 GHz (Dual‑Band)</p>
    <br />

    <p className="label">Operating Modes</p>
    <p className="value">Station Mode (Client)</p>
    <p className="value">Access Point Mode (Configuration)</p>
    <br />

    <p className="label">Network Protocols</p>
    <p className="value"> MQTT, HTTP, HTTPS</p>
    <br />

    <p className="label">Security</p>
    <p className="value">WPA2‑PSK / WPA3</p>
    <p className="value">TLS / SSL Encrypted Communication</p>
    <br />

    <p className="label">IP Configuration</p>
    <p className="value">DHCP / Static IP</p>
    <br />

    <p className="label">Typical Indoor Range</p>
    <p className="value">Up to 100 m (environment dependent)</p>
    <br />
  </div>
</div>

<div class="faint-line"></div>

<div className="spec-block">
  <div className="spec-block-title">
    LED <br /> Status
  </div>
  <div className="spec-block-details">
    <p className="label">LED Type</p>
    <p className="value">1 Internal Multi-Color LED</p>
    <br />
    <p className="label">Solid Blue</p>
    <p className="value">Device is connected with Maya App</p>
    <br />
    <p className="label">Flashing Blue</p>
    <p className="value">OTA (Over-the-Air) update in progress</p>
    <br />
    <p className="label">Slow Blinking Green</p>
    <p className="value">Attempting to connect to the LoRaWAN® network</p>    
    <br />
    <p className="label">Single Red Blink</p>
    <p className="value">A confirmed parameter of MacSync is being modified</p>
    <br />

  </div>
</div>

<div class="faint-line"></div>

<div className="spec-block">
  <div className="spec-block-title">
    Device <br /> Configuration
  </div>
  <div className="spec-block-details">
    <p className="label">Configuration</p>
    <p className="value">Via Macnman Maya Android App</p>
    <br />
    <p className="label">Uplink Modes</p>
    <p className="value">Time Based / Threshold Based / Sampling Based</p>
    <br />
    <p className="label">Stored Records*</p>
    <p className="value">30,000 Records</p>
    <br />
    <p className="label">Remote Configuration</p>
    <p className="value">JSON Format Data - from server</p>    
    <br />
  </div>
</div>

<div class="faint-line"></div>

<div className="spec-block">
  <div className="spec-block-title">
    Supported <br /> Cloud & Platforms
  </div>
  <div className="spec-block-details">
    <p className="label">Deployment Models</p>
    <p className="value">On-Premise Servers</p>
    <p className="value">Private Cloud Deployments</p>
    <p className="value">Public Cloud Platforms</p>
    <br />

    <p className="label">IoT Cloud Platforms</p>
    <p className="value">AWS IoT Core</p>
    <p className="value">Microsoft Azure IoT Hub</p>
    <p className="value">Google Cloud (via MQTT / HTTPS)</p>
    <p className="value">Custom IoT Platforms</p>
    <br />

    <p className="label">Integration Methods</p>
    <p className="value">MQTT Brokers</p>
    <p className="value">REST / HTTPS APIs</p>
    <p className="value">Webhooks</p>
    <br />

    <p className="label">Enterprise Systems</p>
    <p className="value">SCADA Systems</p>
    <p className="value">BMS / IBMS Platforms</p>
    <p className="value">Data Lakes & Analytics Engines</p>
  </div>
</div>

<div class="faint-line"></div>

<div className="spec-block">
  <div className="spec-block-title">
    Physical <br /> Characteristics
  </div>
  <div className="spec-block-details">
    <p className="label">Power Supply</p>
    <p className="value">9-36 V DC</p>
    <br />
    <p className="label">Operating Temperature</p>
    <p className="value">-40°C to +80°C</p>
    <br />
    <p className="label">Humidity Range</p>
    <p className="value">0% to 100% RH (non-condensing)</p>
    <br />
    <p className="label">Ingress Protection</p>
    <p className="value">IP65 standard (IP67 optional variant)</p>    
    <br />
    <p className="label">Housing Material</p>
    <p className="value">Glass field Nylon</p>    
    <br />
    <p className="label">Color</p>
    <p className="value">Matte White</p>    
    <br />
    <p className="label">Weight</p>
    <p className="value">~110g</p>    
    <br />
    <p className="label">Mounting Options</p>
    <p className="value">Pole Mounting / Wall Mounting</p>    
    <br />
  </div>
</div>

<div class="faint-line"></div>

<div className="spec-block">
  <div className="spec-block-title">
    Electrical <br /> Characteristics
  </div>
  <div className="spec-block-details">
    <p className="label">Input Voltage Range</p>
    <p className="value">9-36 V DC (External Supply)</p>
    <br />
    <p className="label">Power Consumption</p>
    <p className="value">~100 µA in sleep mode</p>
    <p className="value">~150 mA during transmission</p>
    <br />
    <p className="label">Input Impedance</p>
    <p className="value">>10 MΩ for voltage inputs</p>
    <br />
  </div>
</div>

<div class="faint-line"></div>

<div className="spec-block">
  <div className="spec-block-title">
    Communication <br /> Options
  </div>
  <div className="spec-block-details">
    <p className="label">BLE Connectivity</p>
    <p className="value">For local configuration and diagnostics via Maya App</p>
    <br />
    <p className="label">Cloud Protocols</p>
    <p className="value">MQTT / HTTPS </p>
    <br />
    <p className="label">Serial Interface</p>
    <p className="value">RS485 Modbus RTU support (optional)</p>
    <br />
  </div>
</div>

<div class="faint-line"></div>

<div className="spec-block">
  <div className="spec-block-title">
    Certifications & <br /> Compliance
  </div>
  <div className="spec-block-details">
    <p className="label">WPC</p>
    <p className="value">Compliant</p>
    <br />
    <p className="label">RoHS</p>
    <p className="value">Conforms to RoHS directive</p>
    <br />
  </div>
</div>

<div class="faint-line"></div>

<div className="spec-block">
  <div className="spec-block-title">
    Security & <br /> Encryption
  </div>
  <div className="spec-block-details">
    <p className="label">Data Encryption</p>
    <p className="value">AES-256 end-to-end encryption</p>
    <br />
    <p className="label">Authentication</p>
    <p className="value">OTAA activation modes</p>
    <br />
    <p className="label">Firmware Protection</p>
    <p className="value">Secure boot and signed OTA updates</p>
    <br />
  </div>
</div>

<div class="faint-line"></div>

##  MacSync-W-Odor-X1 Variants

<table className="parameter-table">
  <thead>
    <tr>
      <th>Variant Name</th>
      <th>Power Source</th>
      <th>Battery Capacity</th>
      <th>Solar Support</th>
      <th>External Flash</th>
      <th>Ideal For</th>
    </tr>
  </thead>
  <tbody>
    <tr>
      <td>MacSync-W-Odor-X1-BO</td>
      <td>Battery</td>
      <td>19 Ah</td>
      <td>✖️</td>
      <td>✔️</td>
      <td>Remote or portable deployments with low power</td>
    </tr>
  </tbody>
</table>

## What's in the box ?

Make sure box contains following items before installations

![Items included in the box: the device, mounting clip, user manual and warranty card, junction box, mounting screws and power adapter](/img/datalogger/whatsbox.svg)

**Accessories must be purchased separately & may :**
not be included in the box.

## Product Dimensions

![MacSync Probe Dimensions](/img/lorawan/sensors/macsync/macsync-probe-dimensions.svg)